Bay Networks 5000 Manual de Serviço Página 153

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 166
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 152
Requirements for European Operation
114200-D Rev 00
D-11
Figure D-6. Cable 7936 (X.21 Compliant)
Table D-10. X.21 Interface (Order No. 7936)
Bay Networks Termination Remote Termination
Pin Signal Pin Signal
2 Send Data+ 2 Transmitted Data A
27 Send Data- 9 Transmitted Data B
4 Request to Send+ 3 Control A
29 Request to Send- 10 Control B
3 Receive Data+ 4 Receive Data A
28 Receive Data- 11 Receive Data B
9 Data Carrier Detect+ 5 Indication A
34 Data Carrier Detect- 12 Indication B
10 Timing+ 6 Timing A
35 Timing- 13 Timing B
1 Frame Ground 1 Frame Ground
7 Signal Ground 8 Signal Ground
Local Wire Connections
Pin 46 > 48 (GRD)
Pin 38 > 40
Pin 14 > 15
15 ft
(4.57 m)
Pin 8
Pin 1
Pin 15
Pin 9
15-position D-sub plug with M-3 jack screws
(ground shield connected to backshell)
Pin 1
Pin 25
Pin 26
Pin 50
50-position 0.8-mm plug
(ground shield connected to internal shell)
CAB0074A
Vista de página 152
1 2 ... 148 149 150 151 152 153 154 155 156 157 158 ... 165 166

Comentários a estes Manuais

Sem comentários