Configuring the Nortel Networks Remote Access Concentrators and the DMS-10 for Remote Access.March 31, 1999 16
If the RAC is being re-deployed and was previously used somewhere else, it is a good
practice to erase the EEPROM and start over. By erasing the EEPROM you insure that
everything is cleared and the default settings are in place.
Once the IP addresses information has been entered, the config information should be
viewed. It is important to look at the WAN downloads that are resident in the unit. A typi-
cal view is shown in figure 8
FIGURE 8. ROM Monitor monitor: prompt type “config”
The current personality load in the WANs needs to be noted if you do not plan on provid-
ing a external load server for the RAC. If there is not a planned external load server (Win-
dows NT or UNIX) there is no way to change the WAN personalities. This is because new
code will need to be loaded into the WAN modules to reconfigure them.
Once it is determined if a external load server is required the boot sequence will need to be
set in the ROM Monitor. The choices are “net” or “self”. Self should be the first choice if
you expect to use the RAC in a stand alone mode.
Once the IP addresses are setup and the boot sequence has been set for your application it
is a good idea to test the network connection by pinging a known address on your IP net-
work both on and off the subnet. If the ping succeeds it’s time to move on to booting the
RAC. If the ping fails the IP address settings need to be verified also the LAN connection
should be inspected. If the device you are pinging is on another subnet try a device that is
local.
Once the LAN is functional, boot the RAC. This will take several minutes. Log messages
will be displayed on the console monitor indicating the state of processes as they come
up.Theses messages are important, they provide a log of the processes starting up.
REVISION/CONFIGURATION INFORMATIONROM
Software Rev: 1124 Board ID: 64 Board Type: 8000
CPU Type: 486DX2 Ethernet Address: 00-80-2d-xx-xx-xx
Memory size: 8 Meg EEPROM size: 65504
Flash size: 4 Meg Flash ID:0089
Available Interfaces (* = selected): ThickNet *Twisted Pair
WAN 1: PRI T1 USA CSU Revision: VERSION A MGR=1.234b
WAN 2: CAS T1 CSU Revision: VERSION CAS-E1T1 1.40
SLC 1
SLC 2
SLC SRAM Size: 128 K Modem Count: 31 Modem Rev: 0
SLC SRAM Size: 128 K Modem Count: 31 Modem Rev: 0
General Purpose Sync Port Interface: No Cable
Compression Card Rev: 0