Configuring the Nortel Networks Remote Access Concentrators and the DMS-10 for Remote Access.March 31, 1999 26
In order to monitor the syslog messages on the console terminal the user will need to be
logged out of CLI and the RAC must be in the default state for “annex syslog”. See figure
15 for the view of the syslog parameters.
FIGURE 15. Syslog Event Logging
If you choose logs can be sent to a external logging device. The event logs can be sent to a
Unix 4.3 BSD syslog daemon or the can be sent to a Windows NT server running the Bay
“Annex syslogd” services. Either syslog daemon are set up the same on the RAC.
Setup is simple, the parameters which control the syslog are in the annex syslog menu.
Figure 15 gives an overview of the parameters. The syslog_host IP address must be set to
the device doing the recording. The syslog_facility can likely be left to the default.
syslog_mask should be set to the minimum level of your requirements. Initially debug
might be your choice, but with the quantity of messages that are generated the buffers in
the syslogd device can easily be overflowed.
Table 4 shows the priority levels “high “emergency to low “debug”. When a priority has
been chosen that level plus all higher levels will be reported to the syslogd host.
TABLE 4. Priority Levels for the syslog_mask Parameter
Level Name Description
High emergency Hardware failures.
alert All RAC reboots.
Note
:
If you are in the console monitor in CLI and you want to view
syslog messages, type “ha” (hangup). This will allow console messages
to be outputted to the console, if no syslog host has been set.
admin : show annex syslog
syslog_mask:*alert,critical,debug,emergency,error,info,notice,warning
syslog_facility: log_local7 syslog_host:*47.39.240.99
syslog_port: 0
This parameter message priority level to be reported. In this exapple
debug was set so all levels will be set. Default none
This is the IP address of the logging host. It can be a Windows NT host
running Bay software or a UNIX device running syslogd.Default 0.0.0.0
This sets the syslog facility. Valid options are log_local0 through
log_local7. Log_local7 is the default..